The first part of the paper, after an introduction on CAD systems, design the various stages of a watertight container for underwater electronic equipment. Calculations are initially made to choose the thickness dimension. Subsequently, with the aid of ISO standards, the gasket and the type of screw are chosen. Finally, each part is modeled in Solid Edge, generating the final assembly. In the second part an accurate components list is compiled, with respective shot peening, of a hydraulic circuit. It consists of two taps, a section of pipe and a manometric sensor that monitors the pressure. The pipe section acts as a test chamber for a subsequent pressure test.
Nella prima parte dell’elaborato, dopo un introduzione sui sistemi CAD, si descrive le varie fasi di progettazione di un recipiente stagno per attrezzatura elettronica subacquea. Inizialmente si svolgono calcoli per scegliere la dimensione dello spessore. Successivamente con l’ausilio delle norme ISO si sceglie la guarnizione e il tipo di vite. Infine, ogni parte si modella in Solid Edge, generando l’assieme finale. Nella seconda parte si compila un accurata distinta componenti, con rispettiva pallinatura, di un circuito idraulico. Esso è formato da due rubinetti, un tratto di tubo e un sensore manometrico che controlla la pressione. Il tratto di tubo funge da camera di prova per un successivo test in pressione.
Progettazione di un recipiente stagno per attrezzatura elettronica subacquea e di una camera di prova in pressione.
CALORE, PIERPAOLO
2019/2020
Abstract
The first part of the paper, after an introduction on CAD systems, design the various stages of a watertight container for underwater electronic equipment. Calculations are initially made to choose the thickness dimension. Subsequently, with the aid of ISO standards, the gasket and the type of screw are chosen. Finally, each part is modeled in Solid Edge, generating the final assembly. In the second part an accurate components list is compiled, with respective shot peening, of a hydraulic circuit. It consists of two taps, a section of pipe and a manometric sensor that monitors the pressure. The pipe section acts as a test chamber for a subsequent pressure test.File | Dimensione | Formato | |
---|---|---|---|
TESI PIERPAOLO CALORE FINALE.pdf
Open Access dal 24/07/2023
Dimensione
1.1 MB
Formato
Adobe PDF
|
1.1 MB | Adobe PDF | Visualizza/Apri |
I documenti in UNITESI sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/20.500.12075/2178