This thesis analyzes data from the Continuous Emissions Monitoring System (CEMS) of the A2A combined-cycle power plant in Gissi. The study focuses on nitrogen oxide (NOx) and carbon monoxide (CO) emissions, evaluating the plant's behavior during normal operation and transient phases. The analysis was conducted using data from 2024 and 2025, comparing emission trends and differences between the plant's two units. The results show generally stable emissions during normal operation, whereas higher emission levels are observed during transient phases. The study confirms the importance of continuous emissions monitoring for assessing the plant's environmental performance and ensuring regulatory compliance.
La presente tesi analizza i dati del Sistema di Monitoraggio Emissioni (SME) della centrale termoelettrica a ciclo combinatoA2a di Gissi. Lo studio si concentra sulle emissioni di ossidi di azoto (NOx) e monossido di carbonio (CO), valutando il comportamento dell'impianto durante il normal funzionamento e nelle fasi di transitorio. L'analisi è stata condotta usando i dati relativi agli anni 2024 e 2025, confrontando l'andamento delle emissioni e le differenze tra le due unità dell'impianto. I risultati evidenziano una stabilità generale delle emissioni durante il normal funzionamento, mentre nelle fasi transitorie osserviamo valori emissivi più elevati. Il lavoro conferma l'importanza del monitoraggio continuo delle emissioni per la valutazione delle prestazioni ambientali dell'impianto e per il rispetto della normativa
ANALISI DATI DEL SISTEMA DI MONITORAGGIO EMISSIONI (SME) IN UNA CENTRALE TERMOELETTRICA A CICLO COMBINATO
CIRULLI, ELENA
2025/2026
Abstract
This thesis analyzes data from the Continuous Emissions Monitoring System (CEMS) of the A2A combined-cycle power plant in Gissi. The study focuses on nitrogen oxide (NOx) and carbon monoxide (CO) emissions, evaluating the plant's behavior during normal operation and transient phases. The analysis was conducted using data from 2024 and 2025, comparing emission trends and differences between the plant's two units. The results show generally stable emissions during normal operation, whereas higher emission levels are observed during transient phases. The study confirms the importance of continuous emissions monitoring for assessing the plant's environmental performance and ensuring regulatory compliance.| File | Dimensione | Formato | |
|---|---|---|---|
|
ANALISI DATI SME 5.pdf
non disponibili
Descrizione: PDF ELABORATO TESI
Dimensione
2.85 MB
Formato
Adobe PDF
|
2.85 MB | Adobe PDF |
I documenti in UNITESI sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/20.500.12075/27967