The objective of the following thesis work is to validate the dynamic calculation method provided by the UNI EN ISO 52016-1:2018 standard. The validation of this methodology was carried out using the dynamic simulation software TRNSYS (TRaNsient SYstem Simulation tool). Two previously analyzed case studies were implemented within the software according to Appendix A and Appendix B of the UNI EN ISO 52016-1:2018 standard. Using the export data obtained from the simulations carried out with TRNSYS, it was possible to compare the useful energy requirements obtained from the three methods proposed (Appendix A, Appendix B, TRNSYS) and to evaluate, on these requirements, the weight of the thermo-physical parameters characterising the building envelope.
L’obbiettivo del seguente lavoro di tesi è convalidare il metodo di calcolo dinamico fornito dalla normativa UNI EN ISO 52016-1:2018. La validazione di tale metodologia è stata effettuata tramite l’ausilio del software di simulazione dinamica TRNSYS (TRaNsient SYstem Simulation tool). All’interno del software sono stati implementati due casi studio già precedentemente analizzati secondo l’appendice A e l’appendice B della norma UNI EN ISO 52016-1:2018. Attraverso i dati di export ricavati dalle simulazioni effettuate con TRNSYS, è stato possibile confrontare i fabbisogni di energia utile ottenuti dai tre metodi proposti (appendice A, appendice B, TRNSYS) e valutare, su tali fabbisogni, il peso dei parametri termo-fisici caratterizzanti l’involucro edilizio.
Analisi di metodi dinamici per la diagnosi energetica degli edifici
SPECA, DANIELE
2019/2020
Abstract
The objective of the following thesis work is to validate the dynamic calculation method provided by the UNI EN ISO 52016-1:2018 standard. The validation of this methodology was carried out using the dynamic simulation software TRNSYS (TRaNsient SYstem Simulation tool). Two previously analyzed case studies were implemented within the software according to Appendix A and Appendix B of the UNI EN ISO 52016-1:2018 standard. Using the export data obtained from the simulations carried out with TRNSYS, it was possible to compare the useful energy requirements obtained from the three methods proposed (Appendix A, Appendix B, TRNSYS) and to evaluate, on these requirements, the weight of the thermo-physical parameters characterising the building envelope.File | Dimensione | Formato | |
---|---|---|---|
Tesi Magistrale Daniele Speca.pdf
Open Access dal 02/06/2023
Descrizione: Tesi Daniele Speca
Dimensione
22.07 MB
Formato
Adobe PDF
|
22.07 MB | Adobe PDF | Visualizza/Apri |
I documenti in UNITESI sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/20.500.12075/4709