The study aims to standardize a measuring procedure to make future studies on freediving techniques comparable to each other. In particular, we focused on detecting the parameters of physiological interest, as much as possible in line with the state of art, and then evaluating their usefulness. After development, the repeatability of the results obtained with the devised protocol was assessed. Then we tried to apply the procedure to evaluate the physiological differences during apnea resulting in two different respiratory techniques. It has been noted that the greater amount of air present in the lungs, after glossopharyngeal respiration, affects the apnea time and the decrease in oxygen saturation in blood. Finally, the number of subjects has increased to assess the comparability of the results obtained from different subjects.

Lo studio ha come obbiettivo lo standardizzare un banco di misura e di una procedura di acquisizione per rendere gli studi futuri sulle tecniche apneistiche confrontabili tra loro. In particolare, ci si è concentrati nel rilevare i parametri di interesse fisiologico, il più in linea possibile con lo stato dell’arte, per poi valutarne l’utilità. Concluso lo sviluppo, si è valutata la ripetibilità dei risultati ottenuti con il protocollo ideato. Poi si è cercato di applicare il banco per valutare le differenze fisiologiche durante l’apnea conseguente due tecniche respiratorie differenti. Si è notato come la maggior quantità d’aria presente nei polmoni, dopo la respirazione glossofaringea, influisca sul tempo d’apnea e sulla diminuzione della saturazione dell’ossigeno nel sangue. Infine, si è aumentato il numero di soggetti per valutare la confrontabilità dei risultati ottenuti da soggetti differenti.

Sviluppo di un banco di misura per la valutazione di tecniche per apnee sportive

MOSCI, SAMUELE
2018/2019

Abstract

The study aims to standardize a measuring procedure to make future studies on freediving techniques comparable to each other. In particular, we focused on detecting the parameters of physiological interest, as much as possible in line with the state of art, and then evaluating their usefulness. After development, the repeatability of the results obtained with the devised protocol was assessed. Then we tried to apply the procedure to evaluate the physiological differences during apnea resulting in two different respiratory techniques. It has been noted that the greater amount of air present in the lungs, after glossopharyngeal respiration, affects the apnea time and the decrease in oxygen saturation in blood. Finally, the number of subjects has increased to assess the comparability of the results obtained from different subjects.
2018
2020-02-25
Development of measuring procedure for the evaluation of freediving techniques
Lo studio ha come obbiettivo lo standardizzare un banco di misura e di una procedura di acquisizione per rendere gli studi futuri sulle tecniche apneistiche confrontabili tra loro. In particolare, ci si è concentrati nel rilevare i parametri di interesse fisiologico, il più in linea possibile con lo stato dell’arte, per poi valutarne l’utilità. Concluso lo sviluppo, si è valutata la ripetibilità dei risultati ottenuti con il protocollo ideato. Poi si è cercato di applicare il banco per valutare le differenze fisiologiche durante l’apnea conseguente due tecniche respiratorie differenti. Si è notato come la maggior quantità d’aria presente nei polmoni, dopo la respirazione glossofaringea, influisca sul tempo d’apnea e sulla diminuzione della saturazione dell’ossigeno nel sangue. Infine, si è aumentato il numero di soggetti per valutare la confrontabilità dei risultati ottenuti da soggetti differenti.
File in questo prodotto:
File Dimensione Formato  
TESI.pdf

Open Access dal 25/02/2023

Dimensione 1.76 MB
Formato Adobe PDF
1.76 MB Adobe PDF Visualizza/Apri

I documenti in UNITESI sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12075/5273