This work is the result of monitoring cardiac activity through wearable / portable sensors during Crossfit training. It analyzed the cardiovascular functioning of the body, starting from the heart up to the entire cardiac cycle, with a focus on monitoring this activity, carried out through the electrocardiogram. We focused on the correspondence between the ECG signal and the action potential, carrying out an in-depth analysis of the fundamental leads. Later we moved on to the study of Crossfit, defining it in its fundamental components and describing its structure and organization of training. The fundamental role of cardiovascular monitoring in sports was highlighted, in particular for two specific aspects: it allows to intervene in a preventive manner on any and unknown heart problems which, if combined with high physical effort, could lead to cardiac death sudden. It also allows you to estimate the intensity of training and improve the athlete's performance. Then the instruments through which it was possible to carry out the monitoring were described, namely the BioHarness sensor by Zephyr and the Kardia sensor by Alivecor. We went to a Crossfit box to monitor the electrocardiographic signal of seven athletes. The athletes monitored were selected by grading the choice based on age, gender, the different ambitions inherent to the level of preparation and, last but not least, based on the type of training. The study was carried out by extracting the different ECG and HR signals and subsequently processing them by defining a plotting code using the “Matlab” software.

Il presente lavoro è il risultato del monitoraggio dell’attività cardiaca attraverso i sensori indossabili / portatili durante l’allenamento Crossfit. Esso ha analizzato il funzionamento cardiovascolare dell’organismo, a partire dal cuore sino all’intero ciclo cardiaco, con un focus di monitoraggio su tale attività, effettuato attraverso l’elettrocardiogramma. Ci si è soffermati sulla corrispondenza tra segnale ECG e potenziale d’azione, effettuando un approfondimento sulle derivazioni fondamentali. Successivamente si è passati allo studio del Crossfit, definendolo nelle componenti fondamentali e descrivendone la struttura e l’organizzazione dell’allenamento. Si è evidenziato il ruolo di fondamentale importanza del monitoraggio cardiovascolare in ambito sportivo, in particolare per due specifici aspetti: esso permette di intervenire in maniera preventiva su eventuali e ignoti problemi cardiaci che, se combinati con un elevato sforzo fisico, potrebbero portare a morte cardiaca improvvisa. Inoltre, consente di stimare l’intensità dell’allenamento e di migliorare la performance dell’atleta. Quindi sono stati descritti gli strumenti attraverso i quali è stato possibile effettuare il monitoraggio, ossia il sensore BioHarness della Zephyr e il sensore Kardia di Alivecor. Ci si è recati in un box di Crossfit per monitore il segnale elettrocardiografico di sette atleti. Gli atleti monitorati sono stati selezionati graduando la scelta in base all’età, al genere, alle diverse ambizioni inerenti il livello di preparazione e, non ultimo, in base alla tipologia di allenamento. Lo studio è stato effettuato estraendo i diversi segnali ECG e HR e successivamente, elaborandoli definendo un codice di plottaggio attraverso il software “Matlab”.

MONITORAGGIO DELL’ATTIVITÀ CARDIACA MEDIANTE SENSORISTICA INDOSSABILE/PORTATILE DURANTE IL CROSSFIT

BERNAVA, CHIARA
2021/2022

Abstract

This work is the result of monitoring cardiac activity through wearable / portable sensors during Crossfit training. It analyzed the cardiovascular functioning of the body, starting from the heart up to the entire cardiac cycle, with a focus on monitoring this activity, carried out through the electrocardiogram. We focused on the correspondence between the ECG signal and the action potential, carrying out an in-depth analysis of the fundamental leads. Later we moved on to the study of Crossfit, defining it in its fundamental components and describing its structure and organization of training. The fundamental role of cardiovascular monitoring in sports was highlighted, in particular for two specific aspects: it allows to intervene in a preventive manner on any and unknown heart problems which, if combined with high physical effort, could lead to cardiac death sudden. It also allows you to estimate the intensity of training and improve the athlete's performance. Then the instruments through which it was possible to carry out the monitoring were described, namely the BioHarness sensor by Zephyr and the Kardia sensor by Alivecor. We went to a Crossfit box to monitor the electrocardiographic signal of seven athletes. The athletes monitored were selected by grading the choice based on age, gender, the different ambitions inherent to the level of preparation and, last but not least, based on the type of training. The study was carried out by extracting the different ECG and HR signals and subsequently processing them by defining a plotting code using the “Matlab” software.
2021
2022-07-21
MONITORING OF HEART ACTIVITY BY MEANS OF WEARABLE / PORTABLE SENSORS DURING THE CROSSFIT
Il presente lavoro è il risultato del monitoraggio dell’attività cardiaca attraverso i sensori indossabili / portatili durante l’allenamento Crossfit. Esso ha analizzato il funzionamento cardiovascolare dell’organismo, a partire dal cuore sino all’intero ciclo cardiaco, con un focus di monitoraggio su tale attività, effettuato attraverso l’elettrocardiogramma. Ci si è soffermati sulla corrispondenza tra segnale ECG e potenziale d’azione, effettuando un approfondimento sulle derivazioni fondamentali. Successivamente si è passati allo studio del Crossfit, definendolo nelle componenti fondamentali e descrivendone la struttura e l’organizzazione dell’allenamento. Si è evidenziato il ruolo di fondamentale importanza del monitoraggio cardiovascolare in ambito sportivo, in particolare per due specifici aspetti: esso permette di intervenire in maniera preventiva su eventuali e ignoti problemi cardiaci che, se combinati con un elevato sforzo fisico, potrebbero portare a morte cardiaca improvvisa. Inoltre, consente di stimare l’intensità dell’allenamento e di migliorare la performance dell’atleta. Quindi sono stati descritti gli strumenti attraverso i quali è stato possibile effettuare il monitoraggio, ossia il sensore BioHarness della Zephyr e il sensore Kardia di Alivecor. Ci si è recati in un box di Crossfit per monitore il segnale elettrocardiografico di sette atleti. Gli atleti monitorati sono stati selezionati graduando la scelta in base all’età, al genere, alle diverse ambizioni inerenti il livello di preparazione e, non ultimo, in base alla tipologia di allenamento. Lo studio è stato effettuato estraendo i diversi segnali ECG e HR e successivamente, elaborandoli definendo un codice di plottaggio attraverso il software “Matlab”.
File in questo prodotto:
File Dimensione Formato  
Tesi Chiara DEFINITIVA_ultima versione.pdf

accesso aperto

Dimensione 2.87 MB
Formato Adobe PDF
2.87 MB Adobe PDF Visualizza/Apri

I documenti in UNITESI sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12075/9543