This thesis examines the main fat signal suppression techniques used in magnetic resonance imaging: CHESS/FatSat, SPIR, SPAIR, Water Excitation, Dixon, and STIR. Through a narrative review of the literature, their advantages, limitations, and clinical applications are compared in terms of fat suppression uniformity, signal-to-noise ratio, artifacts, compatibility with contrast agents, and acquisition times. The aim is to identify practical criteria to help radiologic technologists select the most appropriate technique according to the anatomical region, clinical question, and patient conditions. The comparison highlights that no single technique is universally superior and that examination quality also depends on appropriate acquisition settings and image quality assessment.
La presente tesi analizza le principali tecniche di soppressione del segnale del grasso in risonanza magnetica: CHESS/FatSat, SPIR, SPAIR, Water Excitation, Dixon e STIR. Attraverso una revisione della letteratura, vengono confrontati vantaggi, limiti e applicazioni cliniche, considerando uniformità della soppressione, rapporto segnale-rumore, artefatti, compatibilità con il mezzo di contrasto e tempi di acquisizione. L’obiettivo è individuare criteri utili al TSRM per scegliere la metodica più appropriata in relazione al distretto anatomico, alla domanda clinica e alle condizioni del paziente. Il confronto evidenzia che nessuna tecnica è universalmente superiore e che la qualità dell’esame dipende anche dalla corretta impostazione delle acquisizioni e dal controllo delle immagini.
TECNICHE DI SOPPRESSIONE DEL SEGNALE DEL GRASSO IN RISONANZA MAGNETICA: CRITICITÀ E APPLICAZIONI
CAVALLETTI, MICHELE
2025/2026
Abstract
This thesis examines the main fat signal suppression techniques used in magnetic resonance imaging: CHESS/FatSat, SPIR, SPAIR, Water Excitation, Dixon, and STIR. Through a narrative review of the literature, their advantages, limitations, and clinical applications are compared in terms of fat suppression uniformity, signal-to-noise ratio, artifacts, compatibility with contrast agents, and acquisition times. The aim is to identify practical criteria to help radiologic technologists select the most appropriate technique according to the anatomical region, clinical question, and patient conditions. The comparison highlights that no single technique is universally superior and that examination quality also depends on appropriate acquisition settings and image quality assessment.| File | Dimensione | Formato | |
|---|---|---|---|
|
TESI CAVALLETTI RM pdfA.pdf
non disponibili
Dimensione
1.1 MB
Formato
Adobe PDF
|
1.1 MB | Adobe PDF |
I documenti in UNITESI sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/20.500.12075/29826